MTConnect 2.8 class

EquipmentMode

EQUIPMENT_MODE

Introduced in MTConnect 1.4.

Inheritance

Base classes, from the immediate parent to the root:

  1. Event
  2. Observation
  3. Observation
  4. Thing

Subclasses

EquipmentMode.Delay

elapsed time of a temporary halt of action.

EquipmentMode.Loaded

indication that the sub-parts of a piece of equipment are under load.

Example: For traditional machine tools, this is an indication that the cutting tool is assumed to be engaged with the part.

EquipmentMode.Operating

indication that the major sub-parts of a piece of equipment are powered or performing any activity whether producing a part or product or not.

Example: For traditional machine tools, this includes when the piece of equipment is WORKING or it is idle.

EquipmentMode.Powered

indication that primary power is applied to the piece of equipment and, as a minimum, the controller or logic portion of the piece of equipment is powered and functioning or components that are required to remain on are powered.

Example: Heaters for an extrusion machine that required to be powered even when the equipment is turned off.

EquipmentMode.Working

indication that a piece of equipment is performing any activity, the equipment is active and performing a function under load or not.

Example: For traditional machine tools, this includes when the piece of equipment is LOADED, making rapid moves, executing a tool change, etc.

Properties

Includes inherited members. Defined by identifies the class that declares each member.

NameTypeMultiplicityIntroducedDeprecatedDefined byDefinition
resultEquipmentModeEnum0..1EquipmentMode

Access: public

Aggregation: composite

subTypeDataItemSubTypeEnumEquipmentMode

Access: public

Aggregation: composite

typeEventEnumEquipmentMode

Default: EQUIPMENT_MODE

Access: public

Modifier: static

Aggregation: composite

compositionIdstring0..11.4Observation (inherited)

identifier of the Composition entity defined in the MTConnectDevices Response Document associated with the data reported for the Observation.

Access: public

Modifier: static

dataItemIdstring11.0Observation (inherited)

unique identifier of the DataItem associated with this Observation.

dataItemId MUST match the associated id defined in the MTConnectDevices Response Document.

Access: public

Modifier: static

deprecatedboolean0..12.5Observation (inherited)

indicates if the Observation has any property or controlled vocabulary that has been deprecated in the MTConnect Standard.

Default: false

Access: private

Aggregation: composite

extendedboolean0..12.5Observation (inherited)

indicates if the Observation has any property or controlled vocabulary that has been extended and cannot be validated.

Default: false

Access: private

Aggregation: composite

isUnavailableboolean11.0Observation (inherited)

when true, result is indeterminate.

Note 1 to entry: In XML, when isUnavailable is true, the XML CDATA of the Observation MUST be UNAVAILABLE.

<Execution dataItemId="..." ...>UNAVAILABLE</Execution>

Note 2 to entry: In JSON, when isUnavailable is true, the JSON value of the Observation MUST be UNAVAILABLE.

  "Execution" : [ { "dataItemId": "..." ..., "value": "UNAVAILABLE" } ]

Default: true

Access: public

Aggregation: composite

made byengineered system1Observation (inherited)

Access: private

namestring0..11.0Observation (inherited)

name of the DataItem associated with this Observation.

name MUST match the associated name defined in the MTConnectDevices Response Document.

Access: public

Modifier: static

qualityQualityEnum0..12.5Observation (inherited)

indicates if the Observation is verifiable and is in accordance with the normative definitions within the MTConnect Standard.

Default: UNVERIFIABLE

Access: private

Aggregation: composite

resetTriggeredResetTriggeredEnum0..11.4Event (inherited)

identifies when a reported value has been reset and what has caused that reset to occur for those DataItem entities that may be periodically reset to an initial value.

resetTriggered MUST only be provided for the specific occurrence of a DataItem reported in the MTConnectStreams Response Document when the reset occurred.

Access: public

sequenceinteger11.0Observation (inherited)

number representing the sequential position of an occurrence of an observation in the data buffer of an agent.

sequence MUST have a value represented as an unsigned 64-bit value from 1 to $$ 2^{64}-1 $$.

Access: public

timestampdateTime11.0Observation (inherited)

most accurate time available to a piece of equipment that represents the point in time that the data reported was measured.

Access: public

unitsUnitEnum0..11.0Observation (inherited)

units of the DataItem associated with this Observation.

units MUST match the associated units defined in the MTConnectDevices Response Document.

Access: public

Modifier: static

Aggregation: composite

Relationships

Includes inherited members. Defined by identifies the class that declares each member.

NameTypeMultiplicityIntroducedDeprecatedDefined byDefinition
madeByComponentComponent1Observation (inherited)

Association: Observations

Access: private

madeForDataItemDataItem1Observation (inherited)

Association: Observations

Access: private

organizedByComponentStreamComponentStreamEvent (inherited)

Association: Events

Access: private

Source: MTConnect Institute model documentation, version 2.8.