MTConnect 2.8 package
Sample Types
This section provides semantic information for Sample types.
Classes
- Acceleration
ACCELERATION
- Acceleration.Actual
measured or reported value of an observation.
- Acceleration.Commanded
directive value including adjustments such as an offset or overrides.
- Acceleration.Programmed
directive value without offsets and adjustments.
- AccumulatedTime
ACCUMULATED_TIME
- Amperage
AMPERAGE
- Amperage.Actual
measured or reported value of an observation.
DEPRECATED in Version 1.6.
- Amperage.Alternating
measurement of alternating voltage or current.
If not specified further in statistic, defaults to RMS voltage.
DEPRECATED in Version 1.6.
- Amperage.Direct
measurement of DC current or voltage.
DEPRECATED in Version 1.6.
- Amperage.Target
goal of the operation or process.
DEPRECATED in Version 1.6.
- AmperageAC
AMPERAGE_AC
- AmperageAC.Actual
measured or reported value of an observation.
- AmperageAC.Commanded
directive value including adjustments such as an offset or overrides.
- AmperageAC.Programmed
directive value without offsets and adjustments.
- AmperageDC
AMPERAGE_DC
- AmperageDC.Actual
measured or reported value of an observation.
- AmperageDC.Commanded
directive value including adjustments such as an offset or overrides.
- AmperageDC.Programmed
directive value without offsets and adjustments.
- Angle
ANGLE
- Angle.Actual
measured or reported value of an observation.
- Angle.Commanded
directive value including adjustments such as an offset or overrides.
- AngularAcceleration
ANGULAR_ACCELERATION
- AngularAcceleration.Actual
measured or reported value of an observation.
- AngularAcceleration.Commanded
directive value including adjustments such as an offset or overrides.
- AngularAcceleration.Programmed
directive value without offsets and adjustments.
- AngularDeceleration
ANGULAR_DECELERATION
- AngularDeceleration.Actual
measured or reported value of an observation.
- AngularDeceleration.Commanded
directive value including adjustments such as an offset or overrides.
- AngularDeceleration.Programmed
directive value without offsets and adjustments.
- AngularVelocity
ANGULAR_VELOCITY
- AssetUpdateRate
ASSET_UPDATE_RATE
- AxisFeedrate
AXIS_FEEDRATE
- AxisFeedrate.Actual
measured or reported value of an observation.
- AxisFeedrate.Commanded
directive value including adjustments such as an offset or overrides.
- AxisFeedrate.Jog
relating to momentary activation of a function or a movement.
DEPRECATION WARNING: May be deprecated in the future.
- AxisFeedrate.Override
operator's overridden value.
- AxisFeedrate.Programmed
directive value without offsets and adjustments.
- AxisFeedrate.Rapid
performing an operation faster or in less time than nominal rate.
- BatteryCapacity
BATTERY_CAPACITY
- BatteryCapacity.Actual
measured or reported value of an observation.
- BatteryCapacity.Target
goal of the operation or process.
- BatteryCharge
BATTERY_CHARGE
- BatteryCharge.Actual
measured or reported value of an observation.
- BatteryCharge.Target
goal of the operation or process.
- CapacityFluid
CAPACITY_FLUID
- CapacitySpatial
CAPACITY_SPATIAL
- ChargeRate
CHARGE_RATE
- ChargeRate.Actual
measured or reported value of an observation.
- ChargeRate.Target
goal of the operation or process.
- Concentration
CONCENTRATION
- Conductivity
CONDUCTIVITY
- CuttingSpeed
CUTTING_SPEED
- CuttingSpeed.Actual
measured or reported value of an observation.
- CuttingSpeed.Commanded
directive value including adjustments such as an offset or overrides.
- CuttingSpeed.Programmed
directive value without offsets and adjustments.
- Deceleration
DECELERATION
- Deceleration.Actual
measured or reported value of an observation.
- Deceleration.Commanded
directive value including adjustments such as an offset or overrides.
- Deceleration.Programmed
directive value without offsets and adjustments.
- Density
DENSITY
- DepositionAccelerationVolumetric
DEPOSITION_ACCELERATION_VOLUMETRIC
- DepositionAccelerationVolumetric.Actual
measured or reported value of an observation.
- DepositionAccelerationVolumetric.Commanded
directive value including adjustments such as an offset or overrides.
- DepositionDensity
DEPOSITION_DENSITY
- DepositionDensity.Actual
measured or reported value of an observation.
- DepositionDensity.Commanded
directive value including adjustments such as an offset or overrides.
- DepositionMass
DEPOSITION_MASS
- DepositionMass.Actual
measured or reported value of an observation.
- DepositionMass.Commanded
directive value including adjustments such as an offset or overrides.
- DepositionRateVolumetric
DEPOSITION_RATE_VOLUMETRIC
- DepositionRateVolumetric.Actual
measured or reported value of an observation.
- DepositionRateVolumetric.Commanded
directive value including adjustments such as an offset or overrides.
- DepositionVolume
DEPOSITION_VOLUME
- DepositionVolume.Actual
measured or reported value of an observation.
- DepositionVolume.Commanded
directive value including adjustments such as an offset or overrides.
- DewPoint
DEW_POINT
- Diameter
DIAMETER
- DischargeRate
DISCHARGE_RATE
- DischargeRate.Actual
measured or reported value of an observation.
- DischargeRate.Target
goal of the operation or process.
- Displacement
DISPLACEMENT
- DisplacementAngular
DISPLACEMENT_ANGULAR
Note: The displacement vector MAY be defined by the motion of the owning
Component.- DisplacementLinear
DISPLACEMENT_LINEAR
Note: The displacement vector MAY be defined by the motion of the owning
Component.- ElectricalEnergy
ELECTRICAL_ENERGY
- Elevation
ELEVATION
- Elevation.GroundLevel
ELEVATION where the fixed reference point is GROUND_LEVEL
- Elevation.MeanSeaLevel
ELEVATION where the fixed reference point is MEAN_SEA_LEVEL
- EquipmentTimer
EQUIPMENT_TIMER
- EquipmentTimer.Delay
elapsed time of a temporary halt of action.
- EquipmentTimer.Loaded
time that the sub-parts of a piece of equipment are under load.
Example: For traditional machine tools, this is a measurement of the time that the cutting tool is assumed to be engaged with the part.
- EquipmentTimer.Operating
time that the major sub-parts of a piece of equipment are powered or performing any activity whether producing a part or product or not.
Example: For traditional machine tools, this includes
WORKING, plus idle time.- EquipmentTimer.Powered
time that primary power is applied to the piece of equipment and, as a minimum, the controller or logic portion of the piece of equipment is powered and functioning or components that are required to remain on are powered.
Example: Heaters for an extrusion machine that are required to be powered even when the equipment is turned off.
- EquipmentTimer.Working
time that a piece of equipment is performing any activity the equipment is active and performing a function under load or not.
Example: For traditional machine tools, this includes
LOADED, plus rapid moves, tool changes, etc.- FillHeight
FILL_HEIGHT
- FillHeight.Actual
FILL_HEIGHT that is ACTUAL
- FillHeight.Target
FILL_HEIGHT that is TARGET
- FillLevel
FILL_LEVEL
- Flow
FLOW
- FollowingError
FOLLOWING_ERROR
- FollowingError.Actual
measured or reported value of an observation.
- FollowingErrorAngular
FOLLOWING_ERROR_ANGULAR
- FollowingErrorAngular.Actual
measured or reported value of an observation.
- FollowingErrorLinear
FOLLOWING_ERROR_LINEAR
- FollowingErrorLinear.Actual
measured or reported value of an observation.
- Frequency
FREQUENCY
- GlobalPosition
GLOBAL_POSITION
- GlobalPosition.Actual
measured or reported value of an observation.
- GlobalPosition.Commanded
directive value including adjustments such as an offset or overrides.
- GravitationalAcceleration
GRAVITATIONAL_ACCELERATION
- GravitationalForce
GRAVITATIONAL_FORCE
Note: $$Mass\times GravitationalAcceleration$$
- HumidityAbsolute
HUMIDITY_ABSOLUTE
- HumidityAbsolute.Actual
measured or reported value of an observation.
- HumidityAbsolute.Commanded
directive value including adjustments such as an offset or overrides.
- HumidityRelative
HUMIDITY_RELATIVE
- HumidityRelative.Actual
measured or reported value of an observation.
- HumidityRelative.Commanded
directive value including adjustments such as an offset or overrides.
- HumiditySpecific
HUMIDITY_SPECIFIC
- HumiditySpecific.Actual
measured or reported value of an observation.
- HumiditySpecific.Commanded
directive value including adjustments such as an offset or overrides.
- Length
LENGTH
- Length.Remaining
remaining total length of an object.
- Length.Standard
standard or original length of an object.
- Length.Useable
remaining usable length of an object.
- Level
LEVEL
- LinearForce
LINEAR_FORCE
- Load
LOAD
- Mass
MASS
- ObservationUpdateRate
OBSERVATION_UPDATE_RATE
- Openness
OPENNESS
- Orientation
ORIENTATION
- Orientation.Actual
measured or reported value of an observation.
- Orientation.Commanded
directive value including adjustments such as an offset or overrides.
- PH
PH
- ParticleCount
PARTICLE_COUNT
- ParticleCount.Gas
PARTICLE_COUNT for a GAS
- ParticleCount.Liquid
PARTICLE_COUNT for a LIQUID
- ParticleCount.Solid
PARTICLE_COUNT for a SOLID
- ParticleSize
PARTICLE_SIZE
- PathFeedrate
PATH_FEEDRATE
- PathFeedrate.Actual
measured or reported value of an observation.
- PathFeedrate.Commanded
directive value including adjustments such as an offset or overrides.
- PathFeedrate.Jog
relating to momentary activation of a function or a movement.
DEPRECATION WARNING: May be deprecated in the future.
- PathFeedrate.Override
operator's overridden value.
DEPRECATED in Version 1.3.
- PathFeedrate.Programmed
directive value without offsets and adjustments.
- PathFeedrate.Rapid
performing an operation faster or in less time than nominal rate.
- PathFeedratePerRevolution
PATH_FEEDRATE_PER_REVOLUTION
- PathFeedratePerRevolution.Actual
measured or reported value of an observation.
- PathFeedratePerRevolution.Commanded
directive value including adjustments such as an offset or overrides.
- PathFeedratePerRevolution.Programmed
directive value without offsets and adjustments.
- PathPosition
PATH_POSITION
Example
<DataItem type='PATH_POSITION' id='pathposit1' units="MILLIMETER_3D"/>XML Device Model Example for `PathPosition` using `MILLIMETER_3D` unit
<PathPosition>10.0 0.0 20.0</PathPosition>XML Streams Response Example for `PathPosition` using `MILLIMETER_3D` unit
<DataItem type='PATH_POSITION' id='pathposit1' representation="DATA_SET"> <Definition> <EntryDefinition key='X' units='MILLIMETER'> <EntryDefinition key='Y' units='MILLIMETER'> <EntryDefinition key='Z' units='MILLIMETER'> </Definition> </DataItem>XML Device Model Example for `PathPosition` to demonstrate multi-dimensional representation using `DataSet` representation
<PathPositionDataSet id='pathposit1'> <Entry key='X'>10.0</Entry> <Entry key='Z'>20.0</Entry> </PathPositionDataSet>XML Streams Response Example for `PathPosition` to demonstrate multi-dimensional representation using `DataSet` representation
- PathPosition.Actual
measured or reported value of an observation.
- PathPosition.Commanded
directive value including adjustments such as an offset or overrides.
- PathPosition.Probe
position provided by a measurement probe.
DEPRECATION WARNING: May be deprecated in the future.
- PathPosition.Target
goal of the operation or process.
- Position
POSITION
- Position.Actual
measured or reported value of an observation.
- Position.Commanded
directive value including adjustments such as an offset or overrides.
- Position.Programmed
directive value without offsets and adjustments.
- Position.Target
goal of the operation or process.
- PositionCartesian
POSITION_CARTESIAN
- PowerFactor
POWER_FACTOR
- Pressure
PRESSURE
- PressureAbsolute
The force per unit area measured relative to a vacuum.
- PressurizationRate
PRESSURIZATION_RATE
- PressurizationRate.Actual
measured or reported value of an observation.
- PressurizationRate.Commanded
directive value including adjustments such as an offset or overrides.
- PressurizationRate.Programmed
directive value without offsets and adjustments.
- ProcessTimer
PROCESS_TIMER
- ProcessTimer.Delay
elapsed time of a temporary halt of action.
- ProcessTimer.Process
time from the beginning of production of a part or product on a piece of equipment until the time that production is complete for that part or product on that piece of equipment.
This includes the time that the piece of equipment is running, producing parts or products, or in the process of producing parts.
- Resistance
RESISTANCE
- Resistivity
RESISTIVITY
- RotaryVelocity
ROTARY_VELOCITY
- RotaryVelocity.Actual
measured or reported value of an observation.
- RotaryVelocity.Commanded
directive value including adjustments such as an offset or overrides.
- RotaryVelocity.Override
The operators overridden value.
- RotaryVelocity.Programmed
directive value without offsets and adjustments.
- SettlingError
SETTLING_ERROR
- SettlingError.Actual
measured or reported value of an observation.
- SettlingErrorAngular
SETTLING_ERROR_ANGULAR
- SettlingErrorAngular.Actual
measured or reported value of an observation.
- SettlingErrorLinear
SETTLING_ERROR_LINEAR
- SettlingErrorLinear.Actual
measured or reported value of an observation.
- SoundLevel
SOUND_LEVEL
- SoundLevel.AScale
A Scale weighting factor. This is the default weighting factor if no factor is specified
- SoundLevel.BScale
B Scale weighting factor
- SoundLevel.CScale
C Scale weighting factor
- SoundLevel.DScale
D Scale weighting factor
- SoundLevel.NoScale
No weighting factor on the frequency scale
- SpindleSpeed
SPINDLE_SPEED
- SpindleSpeed.Actual
measured or reported value of an observation.
DEPRECATED in Version 1.3.
- SpindleSpeed.Commanded
directive value including adjustments such as an offset or overrides.
DEPRECATED in Version 1.3.
- SpindleSpeed.Override
operator's overridden value.
DEPRECATED in Version 1.3.
- Strain
STRAIN
- Temperature
TEMPERATURE
- Tension
TENSION
- Tilt
TILT
- Torque
TORQUE
- Velocity
VELOCITY
- Viscosity
VISCOSITY
- VoltAmpere
VOLT_AMPERE
- VoltAmpereReactive
VOLT_AMPERE_REACTIVE
- Voltage
VOLTAGE
- Voltage.Actual
measured or reported value of an observation.
DEPRECATED in Version 1.6.
- Voltage.Alternating
alternating voltage or current.
If not specified further in statistic, defaults to RMS voltage.
DEPRECATED in Version 1.6.
- Voltage.Direct
DC current or voltage.
DEPRECATED in Version 1.6.
- Voltage.Target
goal of the operation or process.
DEPRECATED in Version 1.6.
- VoltageAC
VOLTAGE_AC
- VoltageAC.Actual
measured or reported value of an observation.
- VoltageAC.Commanded
directive value including adjustments such as an offset or overrides.
- VoltageAC.Programmed
directive value without offsets and adjustments.
- VoltageDC
VOLTAGE_DC
- VoltageDC.Actual
measured or reported value of an observation.
- VoltageDC.Commanded
directive value including adjustments such as an offset or overrides.
- VoltageDC.Programmed
directive value without offsets and adjustments.
- VolumeFluid
VOLUME_FLUID
- VolumeFluid.Actual
measured or reported value of an observation.
- VolumeFluid.Consumed
reported or measured value of the amount used in the manufacturing process.
- VolumeFluid.Ended
boundary when an activity or an event terminates.
- VolumeFluid.Part
reported or measured value of amount included in the part.
- VolumeFluid.Start
boundary when an activity or an event commences.
- VolumeFluid.Waste
reported or measured value of the amount discarded.
- VolumeSpatial
VOLUME_SPATIAL
- VolumeSpatial.Actual
measured or reported value of an observation.
- VolumeSpatial.Consumed
reported or measured value of the amount used in the manufacturing process.
- VolumeSpatial.Ended
boundary when an activity or an event terminates.
- VolumeSpatial.Part
reported or measured value of amount included in the part.
- VolumeSpatial.Start
boundary when an activity or an event commences.
- VolumeSpatial.Waste
reported or measured value of the amount discarded
- WaterHardness
WATER_HARDNESS
- Wattage
WATTAGE
- Wattage.Actual
measured or reported value of an observation.
- Wattage.Target
goal of the operation or process.
- XDimension
X_DIMENSION
- YDimension
Y_DIMENSION
- ZDimension
Z_DIMENSION
Source: MTConnect Institute model documentation, version 2.8.